As an Amazon Associate and affiliate partner, Menrva Books earns from qualifying purchases. Learn more
This dissertation, "A Dosimetric Comparison of Different Conventional 2D & 3D Treatment Plans of Palliative Spinal Bone Irradiation" by Ruby, Lam,, was obtained from The University of Hong Kong (Pokfulam, Hong Kong) and is being sold pursuant to Creative Commons: Attribution 3.0 Hong Kong License. The content of this dissertation has not been altered in any way. We have altered the formatting in order to facilitate the ease of printing and reading of the dissertation. All rights not granted by the above license are retained by the author. Abstract: Background: External beam radiotherapy is a common and effective modality in treating patients with spinal metastases. Simple field arrangements would be used in conventional 2D radiotherapy including single posterior and anterior-posterior posterior-anterior (AP-PA) opposing fields. Different prescription method, field size and beam weighting was used commonly, and were investigated in this study. 3D conformal radiation therapy (3DCRT) will also be investigated. Dosimetric comparison on dose homogeneity in target volume and the organ at risk (OARs) dose was performed using three-dimensional dosimetric data. Methods: Computed tomography simulation scans of 15 patients with thoracic spinal bone metastases who received conventional 2D radiotherapy were analyzed retrospectively. Five different treatment plans were created for each patient using different radiotherapy technique: (1) single posterior field with oncologists' prescribed field size; (2) single posterior field with ICRU prescription point; (3) single posterior field with local prescription method (85% isodose level prescribed to Dmax); (4) AP-PA opposing fields with AP-PA ratio = 1:2; (5) AP-PA opposing fields with equal weighting. Conformity, homogeneity, minimum, maximum and mean dose of planning target volume (PTV) were compared. (6) 3DCRT with posterior and posterior oblique wedged fields. OARs dose including spinal cord, esophagus, heart, lung an
This dissertation investigates the dosimetric differences between conventional 2D and 3D conformal radiotherapy treatment plans for palliative spinal bone irradiation. The study retrospectively analyzes computed tomography simulation scans of 15 patients with thoracic spinal bone metastases, comparing five different treatment plans using conventional 2D techniques (single posterior field with varying prescription methods and AP-PA opposing fields with different weightings) against a 3DCRT plan. The primary objective is to compare dose homogeneity within the planning target volume (PTV) and the doses delivered to organs at risk (OARs) such as the spinal cord, esophagus, heart, and lungs.
This dissertation presents a detailed dosimetric comparison of various radiotherapy treatment planning techniques for palliative spinal bone irradiation. The methodology focuses on quantitative analysis of dose distribution in both target volumes and organs at risk, employing established dosimetric parameters. The research aims to inform clinical practice by highlighting potential advantages of different planning approaches in managing spinal metastases. The findings are presented within the context of external beam radiotherapy as a common and effective treatment modality.
Page Count:
0
Publication Date:
2017-01-26
Publisher:
BiblioBazaar
ISBN-10:
1361035951
ISBN-13:
9781361035955
No comments yet. Be the first to share your thoughts!